shi shenxing-九游会平台
  • wechat official account for the department
    wechat official account for undergraduate students of the department
    wechat official account for graduate students of the department
    wechat official account for alumni of the department
    wechat official account for the energy internet research institute, tsinghua university
    wechat official account for the sichuan energy internet research institute, tsinghua university

清华大学电机系

清华大学电机系本科生

清华大学电机系研究生

清华大学电机系校友会

清华大学能源互联网创新研究院

faculties

current location: home > faculties > shi shenxing

shi shenxing

associate professeor

research direction

west main building, 3-207 department of electrical engineering, tsinghua university beijing, 100084, p. r. china

shishenxing@tsinghua.edu.cn

010-6278 2894

  • biography
  • teaching
  • research project
  • publications
  • social service

educational background

1999-2006, ph.d, power system automation, tsinghua university, china

1995-1999, bachelor of eng., electrical engineering, northeast institute of electric power, china

work experience

dec, 2012- present, associate professor, tsinghua university, beijing, china

apr, 2008- nov,2012, lecturer, tsinghua university, beijing, china

apr, 2006- mar,2008, post doctor, tsinghua university, beijing, china

may, 2001- may, 2002, engineer, alstom t&d ltd, uk

honors and awards

the first prize of china electrical power technology award, for the achievement of “fault generated traveling waves based protection of power lines”, 2014

the first prize of shannxi science and technology award, for the achievement of “traveling waves based single-phase-to-ground fault feeder selection technology in power distribution system with neutral non-effectively grounded”,2014

the second prize of beijing science and technology award, for the achievement of “protection technology for feeders in power distribution system” , 2010

teaching

(1)undergraduates courses

electrical & electronic technology

protective relaying in power system

(2)postgraduates courses

power system protection

graduate advising

current graduate students

m.s. candidate: yuwei shang, zonghong hu

(1)research interests

power system fault detection and protective relaying

(2)selected academic funds

2012-2016, local information based system protection research, major international cooperation project by national natural science foundation of china

2012-2014, research on feeder protection technology with fault prevention in power distribution system with neutral non-effectively grounded, youth project by national natural science foundation of china

2012-2014, fundamental research on preventive protection in power system, independent research project by tsinghua university

2011-2013, research on key technology of single-terminal travelling waves based fault location in power distribution system with neutral non-effectively grounded, state key laboratory of control and simulation of power system and generation equipment

2010-2013,fault generated travelling waves theory and its application in fault detection in power system, key project by national natural science foundation of china

(3)selected industry projects

2014-2016, heath index theory and its application in power distribution system, electrical power research institute of china

2013-2015, research on prevention of blackout, hebei power grid company

2011-2013, self-healing control technology research for smart distribution system, shaan xi power grid company

(1)selected international journal papers

xinzhou dong, shenxing shi, tao cui, qiang lu. optimizing solution of fault location using single terminal quantities. science in china, series e: technological sciences, v51, no.6, pp 761-772. 6.2008.

xinzhou dong, shenxing shi. identifying single-phase-to-ground fault feeder in neutral noneffectively grounded distribution system using wavelet transform. ieee transactions on power delivery, v23, no.4, pp 1829-1837. oct.2008

(2)selected conference papers

shenxing shi, minxin wu, xinzhou dong, a two-phase electric quantity-based fault location algorithm for power distribution systems,proceedings of 2014 china international conference on electricity distribution (ciced), shenzhen, china, sept 23-26. 2014

shenxing shi, xinzhou dong,traveling waves based fault forecast for feeders in power distribution system,proceedings of 2014 ieee pes general meeting , national harbor, md, july 27-31,2014

yuwei shang, shenxing shi, bin wang, xinzhou dong, jian liu,operation risk assessment for distribution system with photovoltaic substation connections,proceedings of 12th iet international conference on developments in power system protection (dpsp 2014), copenhagen, denmark, march 31-april 3,2014

dong, xinzhou, shi, shenxing, wang, bin, bak, dominik, cao, runbin, ren, li, lan, lan, he, shi'en,the offline accident of the large-scale wind generator system and its protection & control scheme,proceedings of 11th iet international conference on developments in power system protection (dpsp 2012), birmingham, uk, april 23-26,2012

shi, shenxing, dong, xinzhou,prevention and protection of single-phase-to-ground fault in power distribution system with neutral non-effectively grounded,proceedings of 11th iet international conference on developments in power system protection (dpsp 2012), birmingham, uk, april 23-26,2012

shi shenxing, dong xinzhou, wang shiyong, traveling waves based protection relaying of power lines,proceedings of 2011 international conference on advanced power system automation and protection (apap), beijing, china, october 16-20,2011

shenxing shi, bo jiang, xinzhou dong, zhiqian bo,protection of microgrid,proceedings of 10th iet international conference on developments in power system protection (dpsp 2010), manchester, uk, march 29- april 1,2010

xinzhou dong, shenxing shi, bin wang, wei kong, zhiqian bo,feeder automation system based on non-communication protection and control unit,proceedings of 2009 ieee pes general meeting , calgary, ab, canada, july 26-30,2009

shenxing shi, xinzhou dong,faulted feeder selection in neutral non-effectively grounded distribution system using single-phase current traveling wave ,proceedings of 2009 ieee pes general meeting , calgary, ab, canada, july 26-30,2009

(3)selected chinese journal papers

shi shenxing ,xu gang,dong xinzhou,yin diqing,liu kun,wang kai, a field scheme of feeder automation system based on non-communication protection, advanced technology of electrical engineering and energy, vol.32, no. 1, pp. 94 -97 103, jan 2013

shi shenxing,dong xinzhou,wu jiahua,shen dong, self-healing of single-phase grounding fault for power distribution lines, electric power automation equipment, vol.32, no.11, pp. 97 -101, nov 2012.

shi shenxing,ren li,liu zeyu, dong xinzhou,faulty feeder selector based on traveling wave according to iec61850 standard, electric power automation equipment, vol.31, no.3, pp. 131 -134, mar 2011

wang kan, shi shenxing, yang jianming, dong xinzhou,transient traveling-wave-based grounding line selector and its field tests, electric power automation equipment, vol.28, no.6, pp. 118 -121, jun 2008.

shi shenxing, dong xinzhou, study of fault line selection using single-phase current traveling waves, power system protection and control, vol.36, no. 14, pp. 13 -16, jul 2008.

(4)authorized patent

dong xinzhou, shi shenxing, protection method of symmetrical fault in power distribution feeders. cn201210137308.1,china, issued in march, 2015

dong xinzhou, shi shenxing, protection method of asymmetrical fault in power distribution feeders, cn201210138050.7. china, issued in december, 2014

dong xinzhou, wang jun, shi shenxing, travelling waves based protection method for single-phase-to-ground fault in power distribution feeders, cn201210252585.7. issued in december, 2014

dong xinzhou, wang jun, shi shenxing, travelling waves based protection relay for single-phase-to-ground fault in power distribution feeders, cn201210253747.9. issued in october, 2014

dong xinzhou, shi shenxing, wang jun, protection method for single-phase-to-ground fault, cn201010565305.9. issued in september, 2014

dong xinzhou, shi shenxing, wang shiyong, cui liu, wang jun, wang fei, and jiang bo, ultra high speed travelling waves based directional protection method, device and system for high voltage transmission lines, cn201110047582.5. issued in may, 2014

shi shenxing, dong xinzhou, single-phase-to-ground fault self-healing method, cn201110051968.3. issued in april, 2014

shi shenxing, dong xinzhou, single-phase-to-ground fault self-healing device and system, cn201110051967.9. issued in september, 2013

dong xinzhou, wang shiyong, shi shenxing, high speed data acquisition and digital signal processing device, cn201110070210.4. issued in january, 2013

shi shenxing, dong xinzhou, single-phase-to-ground fault diagnosis method and device, cn201010244589.1. issued in october, 2012

li jianhua, dong liangbin, dong xinzhou, shi shenxing, power amplifier to output wide frequency band high current, cn200910243134.5. issued in october, 2012

shi shenxing, dong xinzhou, single-phase-to-ground fault location method and device, cn201010244606.1. issued in may, 2012

wang bin, dong xinzhou, shi shenxing, single ended fault record and location device for one cubic in power substation, cn200910244485.8. issued in december, 2011

dong xinzhou, wang shiyong, shi shenxing, wang bin, transmission lines fault direction identifying device, cn200910238232.x. issued in november, 2011

dong xinzhou, shi shenxing, wang bin, wang shiyong, transmission lines fault direction detection method, cn200910238231.5. issued july 20, 2011

dong xinzhou, ding lei, wang bin, shi shenxing, liu kun, power grid protection method based on local information in power substation, cn200910089563.1. issued in march, 2011

shi shenxing, dong xinzhou, power system fault forecasting method based on travelling waves measurement, cn200910081349.1. issued in march, 2011

shi shenxing, dong xinzhou, on-line power cable insulation monitoring method based on travelling waves measurement, cn200910081348.7. issued on january 12, 2011

dong xinzhou, shi shenxing, cui tao, transient travelling waves based high impedance fault detection method, cn200710303724.3. issued on september 8, 2010

ieee member

iet member

cigre c6 member

csee member

网站地图